What the numbers mean
No vibration analysis background is needed to use Argos. For a first assessment, focus on two values: velocity and temperature.
The two numbers to watch
Section titled “The two numbers to watch”| Value | Unit | Meaning |
|---|---|---|
| Velocity RMS (Velocidade RMS) | mm/s | Overall vibration level of the machine. The main indicator of machine health. |
| Temperature (Temperatura) | °C | Surface temperature at the sensor. A rise can point to friction or insufficient lubrication. |
The other values
Section titled “The other values”| Value | Unit | Meaning |
|---|---|---|
| Acceleration RMS (Aceleração RMS) | g | High-frequency vibration. Rises early when bearings start to wear. |
| Peak (Pico) | g | Largest single amplitude within a measurement. |
| Crest factor | – | Ratio of peak to RMS. High values indicate short impacts, typical of bearing defects. |
| Kurtosis | – | How impulsive the signal is. Values around 3 are normal. |
| Envelope | g | Isolates repetitive small impacts. Used for bearing diagnostics. |
| Speed | rpm | Rotational speed of the shaft. |
| Running hours | h | Accumulated operating time of the machine. |
All values are reported separately for the X, Y and Z axes.
Limits and states
Section titled “Limits and states”Each measuring point has two limits, Attention (Atenção) and Alarm (Alarme), based on the vibration zones of ISO 20816-3. Administrators can adjust them per point.
| Reading | State |
|---|---|
| Below the attention limit | Normal |
| Above the attention limit | Attention |
| Above the alarm limit | Alarm |
The default temperature limits are 80 °C for attention and 95 °C for alarm.
Charts
Section titled “Charts”Each measuring point offers three charts:
- Trend (Tendência): values over time. The best starting point.
- Spectrum (Espectro): vibration by frequency, which helps identify the source of a problem.
- Temperature (Temperatura): temperature over time.