Where to put a sensor
The mounting position determines what the sensor can detect. A good measuring point is on solid metal, as close as possible to a bearing.
An electric motor seen from the side. Two marked spots: on the housing above the bearing at the shaft end, and above the bearing at the fan end.
The four spots on a motor
Section titled “The four spots on a motor”The app offers four standard points on a motor. DE stands for drive end, the side where the shaft exits; NDE stands for non-drive end, the fan side. Select the point closest to where you mount the sensor.
| Point | Location |
|---|---|
| DE top (LA topo) | On top of the housing, at the shaft end. |
| DE side (LA lateral) | On the side of the housing, at the shaft end. |
| NDE top (LOA topo) | On top of the housing, at the fan end. |
| NDE side (LOA lateral) | On the side of the housing, at the fan end. |
Point the logo at the shaft
Section titled “Point the logo at the shaft”Close-up of a sensor on a motor housing. An arrow shows the logo on the sensor pointing along the motor shaft.
The logo on the sensor marks its orientation. Align the sensor so that the logo points toward the motor shaft; this keeps the measurement axes in the app consistent with the machine.
Good and poor mounting surfaces
Section titled “Good and poor mounting surfaces”| Suitable | Not suitable |
|---|---|
| Solid metal close to a bearing | Thin sheet metal |
| Clean, bare metal | Flaking paint, rust or grease |
| Flat surfaces | Fan covers and guards |
| The machine housing | Pipes, cable trays or the base frame |
Other machine types
Section titled “Other machine types”The app supports centrifugal pumps, electric motors, fans, gearboxes, compressors and bearing housings. The same rule applies to all of them: mount on solid metal close to a bearing.